The accuracy of a grading is high simply from always answering “none” when most of the photographs show no finding. This case study uses an AI system and non-specialist physicians reading fundus photographs in diabetes. I evaluated diagnostic accuracy with 3 measures, namely accuracy, balanced accuracy, and weighted kappa, and judged how far each finding could be entrusted to them.
The study setting, disease, variables, and numbers in this article were newly created by me to explain how the analysis was carried out. The numbers were calculated from a randomly generated dataset and do not reflect the content or circumstances of any actual client project.
432 photographs, 3 findings, and unbalanced proportions of grades
The study used 432 fundus photographs (1 per person) from people who visited the ophthalmology department of a single center for diabetes. Three findings, retinal hemorrhage, hard exudates, and neovascularization, were each graded on 3 levels: none, mild, and severe. The reference was the consensus grading of 3 retina specialists, and this was compared with the grading by an image-reading AI system and with the median grading of 6 non-specialist physicians.
In the reference grading, the 3 grades were reasonably spread for hemorrhage, but “none” accounted for 71.3% of the photographs for hard exudates and 87.0% for neovascularization (Table 1).
| Finding | None | Mild | Severe |
|---|---|---|---|
| Retinal hemorrhage | 184 (42.6) | 139 (32.2) | 109 (25.2) |
| Hard exudates | 308 (71.3) | 88 (20.4) | 36 (8.3) |
| Neovascularization | 376 (87.0) | 34 (7.9) | 22 (5.1) |
Not judging diagnostic accuracy by accuracy alone, and comparing differences with the same photographs paired
For neovascularization, answering “none” for every photograph gives an accuracy of 87.0%. I therefore decided to report, alongside accuracy, the balanced accuracy, which averages the proportions graded correctly at each grade, and the weighted kappa, which removes chance agreement and takes the order of the grades into account.
With 3 grades, the ordinary kappa, which counts grading “none” as “mild” and grading it as “severe” as equally wrong, throws information away. I used the weighted kappa, which counts errors more heavily the further apart the grades are, so that the findings could also be compared with one another.
Furthermore, the AI system and the non-specialist physicians graded the same 432 photographs, so both tend to miss on photographs that are hard to read. Instead of calculating separate confidence intervals and comparing them by eye, I resampled with the bootstrap (1,000 samples), keeping the gradings paired by photograph, and obtained the 95% confidence interval for the difference in each measure itself.
Before taking the median of the 6 as the grading of the non-specialist physicians, I checked how well the gradings of the 6 agreed (inter-rater) and whether the same person gave the same grading on reading again (intra-rater).
For neovascularization, the accuracy of the AI system was high, but it was not detecting the finding

| Finding and measure | AI | Non-specialist physicians (median of 6) | Difference (AI − non-specialist physicians) |
|---|---|---|---|
| Retinal hemorrhage | |||
| Accuracy (%)* | 87.0 (84.0 to 90.0) | 77.3 (73.1 to 80.8) | 9.7 (4.9 to 14.8) |
| Balanced accuracy (%)† | 86.3 (83.0 to 89.4) | 78.4 (74.8 to 81.8) | 7.9 (3.2 to 12.9) |
| Weighted kappa‡ | 0.89 (0.86 to 0.92) | 0.82 (0.79 to 0.86) | 0.07 (0.03 to 0.11) |
| Inter-rater intraclass correlation coefficient§ | — | 0.67 (0.63 to 0.70) | — |
| Intra-rater weighted kappa¶ | — | 0.83 to 0.91 | — |
| Hard exudates | |||
| Accuracy (%)* | 84.5 (81.0 to 88.0) | 76.2 (72.2 to 80.1) | 8.3 (3.2 to 13.2) |
| Balanced accuracy (%)† | 76.5 (70.2 to 82.5) | 75.0 (69.6 to 79.9) | 1.4 (-6.7 to 9.1) |
| Weighted kappa‡ | 0.78 (0.72 to 0.84) | 0.73 (0.68 to 0.78) | 0.05 (-0.02 to 0.12) |
| Inter-rater intraclass correlation coefficient§ | — | 0.59 (0.55 to 0.63) | — |
| Intra-rater weighted kappa¶ | — | 0.80 to 0.81 | — |
| Neovascularization | |||
| Accuracy (%)* | 87.0 (84.0 to 89.8) | 74.8 (70.6 to 78.7) | 12.3 (7.4 to 17.1) |
| Balanced accuracy (%)† | 40.8 (35.3 to 47.5) | 75.9 (68.3 to 82.3) | -35.1 (-44.6 to -24.6) |
| Weighted kappa‡ | 0.42 (0.25 to 0.56) | 0.61 (0.52 to 0.69) | -0.19 (-0.35 to -0.03) |
| Inter-rater intraclass correlation coefficient§ | — | 0.52 (0.48 to 0.56) | — |
| Intra-rater weighted kappa¶ | — | 0.71 to 0.81 | — |
* The accuracy from always answering the most common grade (“none”) is 42.6% for retinal hemorrhage, 71.3% for hard exudates, and 87.0% for neovascularization.
† Mean of the sensitivities for each grade (the proportion of photographs at that grade correctly graded as that grade).
‡ Agreement that takes the order of the grades into account and counts disagreements more heavily the further apart the grades are (quadratic weights).
§ Agreement among the gradings of the 6 non-specialist physicians (two-way random-effects model, absolute agreement, single rater).
¶ Agreement with the first reading when 3 physicians graded 100 photographs again 1 month later (range across the 3).
For hemorrhage, the weighted kappa of the AI system was 0.89, higher than the 0.82 of the non-specialist physicians, with a difference of 0.07 (95% CI, 0.03 to 0.11) (Figure 1 and Table 2). For hard exudates the values were 0.78 and 0.73, and the confidence interval for the difference, -0.02 to 0.12, crossed 0, so I could not conclude which was better.

For neovascularization, in contrast, the accuracy of the AI system was 87.0%, higher than the 74.8% of the non-specialist physicians, yet the balanced accuracy was 40.8% versus 75.9% and the weighted kappa 0.42 versus 0.61, with the order reversed. The AI system answered “none” for 95.1% of the 432 photographs and missed 73.2% of the 56 photographs graded mild or severe by the reference (Figure 2).
This 87.0% is the same value as answering “none” for everything, and it does not express the ability to detect neovascularization. The difference in weighted kappa was -0.19 (-0.35 to -0.03), and for this finding the non-specialist physicians can be said to be closer to the reference.
Among the 6 non-specialist physicians, the inter-rater intraclass correlation coefficient was 0.52 to 0.67 and the intra-rater weighted kappa was 0.71 to 0.91: the gradings of the same person were stable, but the variation between people was not small.
Taken together, the statistical conclusion is that the AI system was closer to the reference than the non-specialist physicians in grading hemorrhage, that I could not conclude that there was a difference for hard exudates, and that for neovascularization it missed many photographs despite its high accuracy. Only 22 photographs had severe neovascularization, and the confidence interval for the kappa of the AI system was wide, at 0.25 to 0.56, so evaluating this finding requires confirmation with more photographs that show it.
Work performed and estimated fee
| Item | Details |
|---|---|
| Analysis method | Evaluation of accuracy for 3 findings (accuracy, balanced accuracy, and weighted kappa), and a paired comparison of the AI system and the non-specialist physicians |
| Additional analyses | 95% confidence intervals from 1,000 bootstrap samples, and evaluation of inter-rater agreement (intraclass correlation coefficient) and intra-rater agreement (weighted kappa) |
| Tables prepared | 1 table of the number of photographs at each grade in the reference grading, 1 table of measures of accuracy and reliability; 2 tables in total |
| Figures prepared | 1 figure of weighted kappa for each finding, 1 figure of the correspondence between the AI grading and the reference for neovascularization; 2 figures in total |
| Deliverables | Analysis report (reasons for the choice of methods and discussion of the results), tables of results (Excel), figures (PNG and TIFF), and a draft of the statistical analysis section for the paper. Analysis code is available on request for an additional fee (¥22,000, incl. tax) |
| Estimated time | About 3 weeks from receipt of the data |
| Estimated fee | ¥308,000 (incl. tax) |
The table lists the main analyses only. I also carry out the finer analyses needed to follow a sound statistical process, such as checking distributions and cleaning the data; these, together with after-care with no time limit (answers to your questions after delivery), are included in the fee.